Configuration
Place project defaults in the nearest pyproject.toml:
[tool.linescope]
backend = "scalene"
sample_rate = 250
include = ["mypackage"]
exclude = ["tests", "generated"]
memory = false
gpu = false
spark = false
notebooks = true
display = "end"
output = "linescope.html"
Override project settings for an individual session through profile:
from linescope import profile
with profile(
backend="trace",
display="none",
include=["mypackage"],
memory=False,
) as session:
run_pipeline()
Explicit profile arguments and CLI values override project settings, which
override built-in defaults. Each new session reads project TOML; explicit
options apply only to that session. Settings are validated before collection
starts. Use root when working outside the package root, and include only the
code that belongs to your investigation.
| Setting | Default | Meaning |
|---|---|---|
backend |
"trace" |
Trace on every supported Python version |
sample_rate |
None |
Target samples/sec; Scalene and Tachyon 1000 |
memory |
False |
Request Python-driver memory metrics |
gpu |
False |
Request GPU metrics with Scalene; Trace warns |
spark |
False |
Enable lazy Spark observation; requires existing PySpark |
notebooks |
True |
Capture supported notebook sources |
display |
"end" |
Also "cell", "cell-summary", or "none" |
include |
automatic | Project packages/paths to include |
exclude |
empty | Project packages/paths to exclude |
root |
discovered | Project source boundary |
output |
None |
Explicit report path; otherwise use a temporary file |
sample_rate sets a target. The achieved samples per second can differ
depending on operating-system timer resolution and scheduling settings, as
well as workload and collection overhead. The report shows the measured rate.
output controls the destination used when displaying in a browser. With
display="none", save explicitly with session.save(...).
Full reports display inline automatically in notebooks and open a browser
elsewhere. Choose a destination when showing a report with
session.show(inline=True) or session.show(inline=False); inline is not a
session or project configuration option.
See the configuration API for the definitive signatures.
For a compact inline overview after each notebook cell, set
display="cell-summary". This mode shows only the latest cell's measurements;
open the cumulative report explicitly with session.show() after stopping.